RATINGS
|
60
MINUTE
|
90
MINUTE |
| Single
Swing, Door and Transom |
Pair
Regular or Double Egress |
Single
Swing, Door and Transom |
Pair
Regular or Double Egress |
| Positive
Pressure "S" Label |
Yes* |
Yes* |
Yes* |
Yes* |
| Sizes |
4'x9'
4'x9' DR/TR
Max TR 4'x3' |
8'x8' DE
8'x9' Reg Pair |
4'x9'
4'x9' DR/TR
Max TR 4'x3'-4" |
8'x8' DE (note
8)
8'x9' Reg Pair |
| Protection
Plates |
48"x48"
(note
5) |
48"x48"
(note 5) |
48"x48"
(note 5) |
48"x48"
(note 5) |
| ETP |
Yes
(note
2) |
Yes
(note
2) |
Yes
(note
2) |
Yes
(note
2) |
| Wire
Chase |
Yes |
Yes |
Yes |
Yes |
| Dutch
Door |
4'x8' No vision panel |
N/A |
N/A |
N/A |
| Maximum
Vision Panel |
100 sq. in.
1015 sq. in. (note
4) |
100 sq. in.
1015 sq. in. (note
4) |
100 sq. in.
1015 sq. in. (note
4) |
100 sq. in.
1015 sq. in. (note
4) |
| Maximum
Louver Fusible Link |
38x30 |
38x30 each leaf |
38x30 |
38x30 each leaf |
| Viewers |
Up to 1" in diameter |
Up to 1" in diameter |
Up to 1" in diameter |
Up to 1" in diameter |
| Hinges |
Per NFPA #80 |
Per NFPA #80 |
Per NFPA #80 |
Per NFPA #80 |
| Locks |
Cylindrical unit
mortise |
Cylindrical unit
mortise |
Cylindrical unit mortise |
Cylindrical unit mortise |
| Exit
Devices |
Listed rim, mortise or
vertical rod |
Listed rim, mortise or
vertical rod |
Listed rim, mortise or
vertical rod |
Listed rim, mortise or
vertical rod |
Flush
Bolts
Top/Bottom for Inactive leafs |
N/A |
Listed surface manual
or automatic flush bolts installed with 28 gauge liner
Required Intumescent |
N/A |
Listed surface manual
or automatic flush bolts installed with 28 gauge liner
Required Intumescent |
| Edge
Guards |
Yes
(note
3) |
No |
Yes
(note
3) |
No |
| Concealed
Vertical Rod |
Yes
5" channel required |
Yes 5" channel required f |
Yes 5" channel required |
Yes 5" channel required |
| Concealed
Closers |
Yes
(note
2) |
Yes
(note
2) |
Yes
(note
2) |
Yes
(note
2) |
| Applied
Moldings |
Yes |
Yes |
Yes |
Yes |
| Automatic
Door Bottoms |
Yes
(note
2) |
Yes
(note
2) |
Yes
(note
2) |
Yes
(note
2) |
TESTING: Labeled fire doors have been tested in accordance with
UL 10, CAN 4S 104ULC-S104),
NFPA 252 and UBC 7-2 Fire Door Test Standards. |
Notes:
(1) Special glass and stop
required/max. size 36"x80"
(2) Special blocking required
(3) Special edges required
(4) Special glass and stop required
(5) Special blocking required
(6) No astragal required with special blocking
(7) Special hinges and pivots require additional blocking
(8) Contact factory for hardware options
* Contact factory for max. size and options |
| Labeling:
Testing, Inspection and labeling is by Intertek Testing
Services/Warmock Hersey Inc. Vancouver Door is listed to
manufacture and machine fire rated wood doors. Labels are
affixed to hinge edge at eye level, or on top rail if positive
pressure. |