| RATINGS |
20
MINUTE
|
45
MINUTE
|
| Swing
Door & Transom |
Pair
Regular or Double Egress |
Lead
Lined
Single Swing |
Single
Swing, Door & Transom |
Pair
Regular or Double Egress |
| Positive
Pressure "S" Label |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
| Sizes |
4'x9'
Single
4'x9' DR/TR
Max TR 4'x3' |
Up
to 8'x9'
6'x10'
8'x9' DE |
4'x9' |
4'x9'
4'x9' DR/TR
Max TR 4'x3' |
8'x8'
DE
8'x9' Regular Pair |
| Protection
Plates |
48"x48" |
48"x48" |
48"x48" |
48"x48"
(note 5) |
48"x48"
(note 5) |
| ETP |
Yes
(note 2) |
Yes
(note 2) |
Yes
(note 2) |
Yes
(note 2) |
Yes
(note 2) |
| Wire
Chase |
Yes |
Yes |
Yes |
Yes |
Yes |
| Dutch
Door |
4'x8'
No Vision Panel |
N/A |
N/A |
4'x8'
No Vision Panel |
N/A |
| Maximum
Vision Panel |
1,296
sq. in.
36" Wide
54" High |
1,296
sq. in.
36" Wide
54" High |
N/A |
1,296
sq. in.
2,638 sq. in (note 1) |
1,296
sq. in.
2,638 sq. in (note 1) |
| Maximum
Louver Fusible Link |
N/A |
N/A |
N/A |
38x30 |
38x30
each leaf |
| Viewers |
Up
to 1" Diameter |
Up
to 1" Diameter |
N/A |
Up
to 1" Diameter |
Up
to 1" Diameter |
| Hinges |
Per
NFPA #80 |
Per
NFPA #80 |
Per
NFPA #80 |
Per
NFPA #80 (note 7) |
Per
NFPA #80 (note 7) |
| Locks |
Cylindrical
unit
mortise |
Cylindrical
unit
mortise |
Cylindrical
unit
mortise |
Cylindrical
unit mortise |
Cylindrical
unit mortise |
| Exit
Devices |
Listed
rim,
mortise or
vertical rod |
Listed
rim,
mortise or
vertical rod |
Listed
rim,
mortise or
vertical rod |
Listed
rim, mortise or
vertical rod |
Listed
rim, mortise or
vertical rod |
Flush
Bolts
Top/Bottom for inactive leafs |
N/A |
Listed
surface manual or automatic flush bolts installed with 28
gauge liner |
N/A |
N/A |
Listed
surface manual or automatic flush bolts installed
with 28 gauge liner
Required Intumescents |
| Edge
Guards |
Yes
(note 3) |
No |
Yes
(note 3) |
Yes
(note 3) |
No |
| Concealed
Vertical Rod |
Yes |
Yes,
no channel required |
N/A |
Yes |
Yes |
| Concealed
Closers |
Yes |
Yes |
N/A |
Yes
(note 2) |
Yes
(note 2) |
| Applied
Moldings |
Yes |
Yes |
No |
Yes |
Yes |
| Automatic
Door Bottoms |
Yes |
Yes |
N/A |
Yes
(note 2) |
Yes
(note 2) |
TESTING: Labeled fire doors have been tested in
accordance with UL 10, CAN 4S 104ULC-S104), NFPA 252 and UBC 7-2 Fire Door
Test Standards. |
Labeling: Testing, Inspection and labeling is
by Intertek Testing Services/Warnock Hersey Inc. Vancouver Door is listed to
manufacture and machine fire rated wood doors. Labels are affixed to hinge edge
at eye level, or on top rail if positive pressure. |
Notes: (1) Special glass and stop
required/max. size 36"x80" (2) Special blocking required (3) Special
edges required (4) Special glass and stop required |
(5) Special blocking
required (6) No astragal required with special blocking (7) Special
hinges and pivots require additional blocking (8) Contact factory for
hardware options * Contact factory for max. size and options |